Using the TCS Hydraulic Injector

Below find the instructions on how to inject TCS Flexible Partials using any of the TCS Hydraulic Injector.

Kits Available

Hydraulic Injector Basic and Complete Kits

Basic Kits Includes:

110V   3504-01    |    220V    3504-02

1 Digital Furnace

1 Cylinder with Handle

1 Knock Out Rod
1 Knock Out Stand

1 Thick Bronze Plug
1 Thin Bronze Plug

1 Injection Flask

6 Cartridges of TCS Resins

2 Med. cartridges of each Unbreakable™, iFlex™, and Karadent™ in St. Pink.

1 Mold Release Spray

Complete Kit Includes:

110V     3511-01     |     220V     3511-02

TCS Cartridges

2 pks – Unbreakable™
2 pks – iFlex™
2 pks – Karadent™
(Packs come in Medium St. Pink)

1 Digital Furnace

2 Cylinders with Handle

1 Knock Out Rod
1 Knock Out Stand

2 Thick Bronze Plugs
1 Thin Bronze Plug

2 Injection Flasks

10 pcs. of Palate Wax

10 pcs. of Lingual Wax

10 pcs. of Sprue Wax

3 pcs. of 9.5 Sprue Wax

1 Carving Knife

1 Cement

1 sample of EZ Flow

1 Mold Release Spray

1 Fusing Liquid

1 Hot Air Welder

Twist Drill samples

TCS Putty (400 gms)

1 Econo Cutter
1 Econo Mandrel

1 White Knock Down Wheel & Chuck

1 Rubberized Abrasive 304 & 306

10 Pink Grinding Wheels

10 Brown Rubber Wheels

5 Green Mounted Stones

2 Lg. Rubber Points
2 Sm. Rubber Points

2 Mini Fuzz Buffs

1 Pink Zirconia Coarse Bur

1 lb. of Polycril

1 Turbo Buff

4 Rag Buffs

Sample pieces of Polishing Pastes

1 Sample Model (upon request)

Items in the kits may change without notice. We strive for continuous improvement, if we discover a product that works better with our resins, we may switch out an item(s).

Questions?

Contact Us at
(866)426-2970
(562)426-2970
info@tcsdentalinc.com

Learn More >

How to Use

Instructional Manual

Frequently Asked Questions

What is the difference between the TCS resins?

TCS offers three distinct resins to fabricate removable dental appliances for patients with missing teeth. The characteristics of TCS resins allow lab technicians to create thin and comfortable appliances. Unbreakable™ is a nylon thermoplastic material popularized for its unbeatable strength and excellent elastic memory.  iFlex™ is a polyolefin thermoplastic material famous for its stain-resistant properties, and its simplicity to finish and polish.  Karadent™ is a semi-rigid microcrystalline polymer praised for its strength, stability, and no volume shrinkage. Karadent™ is an upgrade from acrylic dentures that is ideal for full dentures, clear clasps, and frameworks. Meanwhile, Unbreakable™ and iFlex™ are ideal for flexible partial dentures. All TCS resins are capable of easily fabricating BPA and monomer free removable dental appliances that are aesthetic and durable for everyday use.

Which TCS resin is better?

Although all three TCS resins are formulated with aesthetic, functionality, and patient comfort in mind, choosing the right material for a particular case comes down preference and indication.  

Between iFlex™ and Unbreakable™, both offer the same characteristics and functionality for flexible partial dentures. However, iFlex™ offers higher translucency in comparison to Unbreakable ™.  

Unlike iFlex™ and Unbreakable™, Karadent™ is ideal when a full denture, clear framework, or nightguard is prescribed. Additionally, Karadent™ is excellent for partial dentures that require a rigid material, and for large cases where flexibility in the pallet area is not recommended. 

All resins are BPA free and monomer free. For thorough indications and contraindications for each resin please visit Unbreakable™, iFlex™ or  Karadent™.

Which TCS resin lasts longer?

All three of our resins are meant to last a lifetime. Although some of our resins are considered unbreakable, the longevity of an appliance will depend on how well the patient cares for their appliance. We recommend the TCS Concentrated Dental Appliance Cleaner to keep appliances looking and feeling like new. 

Which TCS resin costs the most?

TCS resins are high-quality thermoplastics that come in a variety of cartridge types and sizes with various shades. Prices will vary depending on the cartridge type and size. Furthermore, because TCS does not sell direct, prices will vary depending on the distributor you purchase from. For pricing on TCS resins please contact your distributor or one of our Authorized Distributors.

How many shades do the TCS resins come in? Which shade(s) blends in the best?

Unbreakable™ and iFlex™ are available in 5 shades: Light Pink, Standard Pink, Light/Dark Pink, Dark Pink, and *Natural.  * The TCS Natural shade is a filmy white shade that is virtually invisible when used for a clasp near the abutment tooth. 

Karadent™ is available in 3 shades: Standard Pink, Dark Pink, and Clear.  

We offer free shades guides to use as a reference when matching a patient’s natural gingiva to a shade. Contact us to get your shade guide today.

Which TCS resin is the most flexible?

Out of all the TCS resins, iFlex™ is considered the most flexible. However, depending on the thickness of an appliance, all TCS resins are capable of flexibility. Even Karadent™ may become slightly more flexible with thinness.

Which TCS resin is the most translucent?

iFlex™ offers a slightly higher translucency than Unbreakable™ and Karadent™ finishes completely transparent in shade Clear.

What are the times and temperatures for each TCS resin?

Unbreakable™:  

When using the TCS Manual Injector or the TCS Hydraulic Injector in conjunction with the TCS Digital Furnace or with any injector: 

  • Using 25mm cartridges
    • 550°F (288°C) | 11 min   

When using the TCS Automatic Air Injector 110V: 

  • Using 25mm cartridges
    • 320°C | 11 min | 145 – 150 PSI

iFlex™:  

When using the TCS Manual Injector or the TCS Hydraulic Injector in conjunction with the TCS Digital Furnace or with any injector: 

  • Using 25mm cartridges
    • 450°F (232°C) | 13 min   

When using the TCS Automatic Air Injector 110V: 

  • Using 25mm cartridges
    • 280°C | 13 min | 145 – 150 PSI

Karadent™:  

When using the TCS Manual Injector or the TCS Hydraulic Injector in conjunction with the TCS Digital Furnace or with any injector: 

  • Using 25mm cartridges
    • 550°F (288°C) | 15-16 min   

When using the TCS Automatic Air Injector 110V: 

  • Using 25mm cartridges
    • 320°C | 15-16 min | 150 – 165 PSI
Which of the 3 TCS resins is simplest to finish and polish?

All TCS resins are simple to work with. When it comes to finishing and polishing appliances made with iFlex™ and Unbreakable™, divide the partial into three sections and spend an equal amount of time in each section. Refrain from moving the partial in different directions, unlike acrylic dentures iFlex™ and Unbreakable™ should not be polished all at once. 

Technicians have found that iFlex™ is easier to finish due to its softness. Polyolefin based materials (such as iFlex™) grind easier with less pressure in comparison to nylon-based materials (such as Unbreakable™). 

Karadent™ is very easy to finish and polish because unlike acrylic, it requires less time to complete.

How do I finish and polish the TCS resins?

Unbreakable™:

For best results we recommend using the TCS Pink Zirconia Burs to finish and the Green Hi-Shine polishing paste to polish Unbreakable™.  

Always apply Brown Tripoli with a clean Rag Buff on medium-high pressure before using Green Hi-Shine. Then apply the Green Hi-Shine using a dry Rag Buff at high speed with moderate pressure. 

iFlex™:

For best results, we recommend using the TCS Pink Zirconia Burs to finish and the iShine polishing paste to polish iFlex™. 

Always apply Brown Tripoli with a clean Rag Buff on medium-high pressure before using iShine. Then apply the iShine using a dry Rag Buff at medium-high speed with very light pressure.

Karadent™:

For best results we recommend using the TCS Pink Zirconia Burs or any acrylic burs to finish and the Green Hi-Shine polishing paste to polish Karadent™.  

Always apply Brown Tripoli with a clean Rag Buff on medium-high pressure before using Green Hi-Shine. Then apply the Green Hi-Shine using a dry Rag Buff at high speed with moderate pressure.

For a step by step guide on finishing and polishing TCS resins, please view or download the Finishing and Polishing eBook.

Which TCS resin can be repaired and/or allows for tooth additions?

Yes, a tooth may be added to any TCS appliance. All three TCS resins can be repaired in a laboratory procedure. However, a tooth can only be added using the same material as the original partial.

Unbreakable™ can be repaired with re-injection and a bonding agent, we recommend the TCS Fusing Liquid. View our step by step guide.

iFlex™ can be repaired with re-injection, no bonding agent (or fusing liquid) is needed but always overlap with existing material. Small repairs with the TCS Hot Air Welder are also doable yet, very difficult.

Karadent™  full dentures can be relined with acrylic. Other Karadent™ appliances can repaired with re-injection or a bonding agent (TCS Fusing liquid is recommended) with acrylic. Small repairs with the TCS Hot Air Welder are also doable yet, serve as a temporary ~6-month repair. 

Please contact us for further details and assistance.

Why am I getting bubbles?
Bubbles happen from time to time and can be unavoidable. Some of the most common reasons for air bubbles include: 
  1. Waxing too thick: Waxing too thick is the number 1 reason bubbles often occur. Flexible partials should be waxed approximately 1.5mm thick for small cases with abutment teeth and 2.5 – 3mm where the saddle connects to the abutment teeth in free end saddles. If a thicker wax-up is unavoidable, try to wax as close as possible to the final case.
  2. Incorrect spruing method: When spruing use 2 – 3 sprues at the tip end of a wax-up and be sure the connection between the sprue and the waxed model is thin. Adding too much wax to the connection may cause an air bubble. Avoid placing the sprues too close to the teeth, as this will also cause air bubbles underneath the teeth. Refer to the diagram below for proper placement and sprue thickness.
  3. Not using enough pressure: Use the correct pressure when injecting TCS resins. Injecting slowly or with a low pressure may cause bubbles to develop.
  4. Overheating the flask: If injecting Unbreakable™ or iFlex™, the flask should be at room temperature. (When working with a TCS Automatic Air Injector Unit, DO NOT leave the flask in the injecting position during the entire melt time. Alternatively, position the flask on top of the machine 1 minute before injecting).
  5. Using the wrong cartridge size: Select the right cartridge size on a case by case basis. If a case is larger than the selected cartridge, the material will not fill the case properly, causing bubbles to cover the partial.
Can I fix air bubbles?

The TCS Hot Air Welder can serve as an easy fix for minor air bubbles. Click here to view a Step By Step Guide.

How do I avoid open bites?
  1. Consistency: For a consistent bite reference when waxing, articulate both the duplicate model and the master model to mirror each other. Additionally, practicing the design on the model will result in aconsistent reference point. 
  2. Overestimating: When preparing the model for investing, trim less of the wax-up than desired. It is best practice to have extra finishing room instead of risking a lack of coverage around the edges.
  3. Flask condition: Double-check the condition of your flask before injecting. Your flask should touch metal to metal, and the screw inserts must be stable.
  4. Lightly add separator or Vaseline: Avoid adding excessive amounts of separator or Vaseline. DO NOT apply separator or Vaseline in-between the metal halves as this may tamper the metal to metal contact of the flask.
  5. Use a buff stone: Avoid using anything other than a buff stone for investing. Mixing plaster with buff stone or using a material softer than buff stone is not recommended. Keep in mind that using a material harder than buff stone will make the de-flasking process more difficult. 
  6. Using the TCS Putty correctly: Once a wax-up is invested, apply a thin coating of the TCS Putty around the replacement teeth. Make sure the cusp and incisor edges of the teeth are slightly visible. Before the putty hardens add retentive undercuts on the facial side of the putty.
Why did I get a tooth pop out?
  1. Inadequate diatorics: One of the main reasons for tooth pop-outs is not having a distinct entrance and exit. Be sure to define the diatorics properly.

  2. Separator not drying: If you use a separator that is not the TCS EZ Flow separator, be sure to apply thin layers and allow each layer dry completely. Additionally, avoid creating build-up around the teeth.  

  3. Inaccurate injection: Premature injection or injecting at low pressures prevents the material from properly flowing through the diatoric holes.

  4. Incorrect boil-out: Improper boil-outs leave behind remnants of wax inside the diatoric holes and block the flow of the material when injecting.

  5. Blocked flow: Setting the teeth too close to each other prevents the material from flowing through the diatorics and securing the teeth to the partial.

  6. Tiny Teeth: Using small teeth may result in a pop out due to not having enough stability. It is best practice to avoid using tiny teeth. 
advanced divider

Hydraulic Injector Instructional Manual

The most popular of TCS injection units. Learn how to simple it is to use the TCS Hydraulic Injector.

TCS Automatic Injector Instructional Manual

TCS’s most economical injection unit, the TCS Manual Injector. An overview video on its key characteristics and how to use.

Manual Injector Instructional Manual

TCS’s most economical injection unit, the TCS Manual Injector. An overview video on its key characteristics and how to use.

TCS Duplicating Unit – 2 Gallon Model

A no frills 2 gallon duplicating unit for value.

TCS Digital Furnace Instructional Manual

A reliable and low maintenance furnace used to inject thermoplastic resins. Learn more about the TCS Digital Furnace.

TCS JP90 Handheld Injector Instructional Manual

The only handheld injector in the market capable of injecting from 1-3 tooth unilaterals to 5 consecutive tooth partials/saddles. An overview video on its key characteristics and how to use.

Share

Important

  • Warranty Statement
  • Terms of Sale and Conditions
  • Terms of Use
  • Privacy Policy
  • Contact Us
Facebook Instagram Youtube Linkedin

Shortcuts

  • Labs
  • Dentists
  • Patients
  • Technical Support
  • Authorized Distributors
  • TCS Equipment Rental Program

About

  • About Us
  • History
  • Products
  • Together We Smile
  • International
  • TCS Fresh

Contact Us

(866) 426-2970
(562) 426-2970

8:30 AM – 4:30 PM PST (M-TH)
8:30 AM – 3:45 PM PST (F)

info@tcsdentalinc.com

International
abraham@tcsdentalinc.com
Text Support
(562) 241-1225

Asset 1
© 2020 TCS Dental Inc. All Rights Reserved.
    My account
    0

    $0.00

    • Any questions? Call us
    • (866) 426-2970
    • Authorized Distributors
    • International
    • TCS Fresh
    • Contact Us
    • All Products
    • All Downloads
    • Cart
    ✕

    Login

    Lost your password?